We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Water supply pipe extension device.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Water supply pipe extension device - List of Manufacturers, Suppliers, Companies and Products

Water supply pipe extension device Product List

1~2 item / All 2 items

Displayed results

[Case Study on Wastewater BOD and Sludge Reduction] Ricoh Company, Ltd. Ebina Factory

We will introduce a case study of a lab test for reducing excess sludge treatment costs!

We would like to introduce a case study of a laboratory test conducted at Ricoh's Ebina Plant to reduce excess sludge treatment costs. As a result of three BOD comparison tests, an average reduction of approximately 20% in BOD was confirmed. In this test, the wastewater was diluted by half. However, in actual use, since the entire wastewater is modified, a BOD reduction of about 40%, which is double the test results, can be expected. 【Method of BOD Laboratory Test】 1. Collect 1 liter each of inflow and outflow water from Ricoh's Ebina Plant. 2. Divide the inflow into 500ml portions, labeling them A and B. Similarly, divide the outflow into 500ml portions. Further, modify inflow A with BW (Bio Water). 3. Mix inflow A with outflow A, and inflow B with outflow B (since it's 500ml each, the ratio is 1 to 1). 4. Measure the BOD of the BW-treated water and untreated water (using the 20°C 7-day incubation method). *For more details, please refer to the PDF document or feel free to contact us. *The section titled 'Reason for Interest' displayed during the PDF download is generated by AI from Ipros Inc.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Magnetite Pipe Method Case Study] Shibaura Mechatronics Corporation Building No. 2

The shape and quality of the rust that can form are completely different, and it has been confirmed that it is effective in preventing the deterioration of the water supply pipes!

Here is a case study of Shibaura Mechatronics Co., Ltd. Building No. 2 (Yokohama City, Kanagawa Prefecture). The water from the circulating water system's cushion tank (WT2) was treated with The Bio Water. As a comparison, the cushion tank (T2) from the clean room air conditioning system was used as an untreated control tank. Test pieces were placed in each tank for comparison. As a result, it was confirmed that the shape and quality of rust that could form were completely different with and without The Bio Water, demonstrating its effectiveness in preventing the deterioration of the water supply pipes. 【Test Pieces Used】 - Two types were set: thin plates of soft iron (Test Piece 1) and joints of GP pipes with the zinc plating removed (Test Piece 2). - Five sets of each were placed in each tank. *For more details, please refer to the PDF document or feel free to contact us. *The section titled 'Reason for Interest' displayed during PDF download is generated by the AI of Ipros Co., Ltd.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration